Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Imaging Radiat Oncol ; 19: 85-89, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34355071

RESUMO

BACKGROUND AND PURPOSE: Magnetic resonance (MR) guided radiotherapy utilizes MR images for (online) plan adaptation and image guidance. The aim of this study was to investigate the impact of variation in MR acquisition time and scan resolution on image quality, interobserver variation in contouring and interobserver variation in registration. MATERIALS AND METHODS: Nine patients with prostate cancer were included. Four T2-weighted 3D turbo spin echo (T2w 3D TSE) sequences were acquired with different acquisition times and resolutions. Two radiologists assessed image quality, conspicuity of the capsule, peripheral zone and central gland architecture and motion artefacts on a 5 point scale. Images were delineated by two radiation oncologists and interobserver variation was assessed by the 95% Hausdorff distance. Seven observers registered the MR images on the planning CT. Registrations were compared on systematic offset and interobserver variation. RESULTS: Acquisition times ranged between 1.3 and 6.3 min. Overall image quality and capsule definition were significantly worse for the MR sequence with an acquisition time of 1.3 min compared to the other sequences. Median 95% Hausdorff distance showed no significant differences in interobserver variation of contouring. Systematic offset and interobserver variation in registration were small (<1 mm) and of no clinical significance. CONCLUSIONS: Our results can be used to effectively shorten overall fraction time for online adaptive MR guided radiotherapy by optimising the imaging sequence used for registration. From the sequences studied, a sequence of 3.1 min with anisotropic voxels of 1.2 × 1.2 × 2.4 mm3 provided the shortest acquisition time without compromising image quality.

2.
Artigo em Inglês | MEDLINE | ID: mdl-34007911

RESUMO

AIM: Breast radiotherapy accounts for a significant workload in radiotherapy departments. In 2015 it became clinical practice at the Netherlands Cancer Institute for radiation therapists (RTTs) to delineate the clinical target volume of the breast tissue (CTVbreast) and in 2017 axilla level I-II (CTVln12) according to a delineation atlas. All RTTs were trained and got individual feedback. The aim of this retrospective study was to investigate the variation between the CTVbreast with or without CTVln12 delineated by a trained group of radiation therapists and the clinical adjusted delineations by the radiation oncologist/physician assistant (RO/PA), in a large group of patients treated between January 2017 and June 2020. MATERIALS AND METHODS: 1012 computer tomography based delineations of CTVbreast and 146 of CTVln12 were collected from January 2017-June 2020. The RTT and RO/PA delineations were compared using the Dice coefficient and the 95th percentile Hausdorff Distance (95%HD). Statistical significance of the differences was tested using a Mann-Whitney test. RESULTS: Differences in CTVbreast delineations were small. A median Dice score of 1.00 for all years, where 83% of the patients had a Dice score > 0.99. For CTVln12 the magnitude of edits made by RO/PAs decreased over time, with the Dice increasing from a median of 0.87 in 2017 to 0.90 in 2020 (p = 0.031). The 95%HD decreased from a median of 0.93 cm in 2017 to 0.61 cm in 2020 (p = 0.051). CONCLUSIONS: This retrospective study shows that trained dedicated RTTs are capable in delivering the same quality delineations as RO/PAs. The low variability supports the increasing role of RTTs in the contouring process, likely making it more time efficient.

4.
Phys Med Biol ; 61(4): 1780-94, 2016 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-26854384

RESUMO

The Pareto front reflects the optimal trade-offs between conflicting objectives and can be used to quantify the effect of different beam configurations on plan robustness and dose-volume histogram parameters. Therefore, our aim was to develop and implement a method to automatically approach the Pareto front in robust intensity-modulated proton therapy (IMPT) planning. Additionally, clinically relevant Pareto fronts based on different beam configurations will be derived and compared to enable beam configuration selection in cervical cancer proton therapy. A method to iteratively approach the Pareto front by automatically generating robustly optimized IMPT plans was developed. To verify plan quality, IMPT plans were evaluated on robustness by simulating range and position errors and recalculating the dose. For five retrospectively selected cervical cancer patients, this method was applied for IMPT plans with three different beam configurations using two, three and four beams. 3D Pareto fronts were optimized on target coverage (CTV D(99%)) and OAR doses (rectum V30Gy; bladder V40Gy). Per patient, proportions of non-approved IMPT plans were determined and differences between patient-specific Pareto fronts were quantified in terms of CTV D(99%), rectum V(30Gy) and bladder V(40Gy) to perform beam configuration selection. Per patient and beam configuration, Pareto fronts were successfully sampled based on 200 IMPT plans of which on average 29% were non-approved plans. In all patients, IMPT plans based on the 2-beam set-up were completely dominated by plans with the 3-beam and 4-beam configuration. Compared to the 3-beam set-up, the 4-beam set-up increased the median CTV D(99%) on average by 0.2 Gy and decreased the median rectum V(30Gy) and median bladder V(40Gy) on average by 3.6% and 1.3%, respectively. This study demonstrates a method to automatically derive Pareto fronts in robust IMPT planning. For all patients, the defined four-beam configuration was found optimal in terms of plan robustness, target coverage and OAR sparing.


Assuntos
Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias do Colo do Útero/radioterapia , Feminino , Humanos
5.
Phys Med Biol ; 57(10): 2943-52, 2012 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-22516969

RESUMO

To evaluate in an objective way the effect of leaf interdigitation and leaf width on volumetric modulated arc therapy plans in Pinnacle. Three multileaf collimators (MLCs) were modeled: two 10 mm leaf width MLCs, with and without interdigitating leafs, and a 5 mm leaf width MLC with interdigitating leafs. Three rectum patients and three prostate patients were used for the planning study. In order to compare treatment techniques in an objective way, a Pareto front comparison was carried out. 200 plans were generated in an automated way, per patient per MLC model, resulting in a total of 3600 plans. From these plans, Pareto-optimal plans were selected which were evaluated for various dosimetric variables. The capability of leaf interdigitation showed little dosimetric impact on the treatment plans, when comparing the 10 mm leaf width MLC with and without leaf interdigitation. When comparing the 10 mm leaf width MLC with the 5 mm leaf width MLC, both with interdigitating leafs, improvement in plan quality was observed. For both patient groups, the integral dose was reduced by 0.6 J for the thin MLC. For the prostate patients, the mean dose to the anal sphincter was reduced by 1.8 Gy and the conformity of the V(95%) was reduced by 0.02 using the thin MLC. The V(65%) of the rectum was reduced by 0.1% and the dose homogeneity with 1.5%. For rectum patients, the mean dose to the bowel was reduced by 1.4 Gy and the mean dose to the bladder with 0.8 Gy for the thin MLC. The conformity of the V(95%) was equivalent for the 10 and 5 mm leaf width MLCs for the rectum patients. We have objectively compared three types of MLCs in a planning study for prostate and rectum patients by analyzing Pareto-optimal plans which were generated in an automated way. Interdigitation of MLC leafs does not generate better plans using the SmartArc algorithm in Pinnacle. Changing the MLC leaf width from 10 to 5 mm generates better treatment plans although the clinical relevance remains to be proven.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Radiometria , Neoplasias Retais/radioterapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...